Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1984 1
1986 3
1989 1
1997 1
2001 1
2002 1
2003 1
2004 2
2005 1
2006 1
2007 2
2008 2
2009 3
2010 1
2011 2
2012 2
2013 2
2015 2
2016 2
2017 5
2018 6
2019 2
2021 2
2022 5
2023 2
2024 2

Text availability

Article attribute

Article type

Publication date

Search Results

51 results

Results by year

Filters applied: . Clear all
Page 1
36th International Symposium on Intensive Care and Emergency Medicine : Brussels, Belgium. 15-18 March 2016.
Bateman RM, Sharpe MD, Jagger JE, Ellis CG, Solé-Violán J, López-Rodríguez M, Herrera-Ramos E, Ruíz-Hernández J, Borderías L, Horcajada J, González-Quevedo N, Rajas O, Briones M, Rodríguez de Castro F, Rodríguez Gallego C, Esen F, Orhun G, Ergin Ozcan P, Senturk E, Ugur Yilmaz C, Orhan N, Arican N, Kaya M, Kucukerden M, Giris M, Akcan U, Bilgic Gazioglu S, Tuzun E, Riff R, Naamani O, Douvdevani A, Takegawa R, Yoshida H, Hirose T, Yamamoto N, Hagiya H, Ojima M, Akeda Y, Tasaki O, Tomono K, Shimazu T, Ono S, Kubo T, Suda S, Ueno T, Ikeda T, Hirose T, Ogura H, Takahashi H, Ojima M, Kang J, Nakamura Y, Kojima T, Shimazu T, Ikeda T, Suda S, Izutani Y, Ueno T, Ono S, Taniguchi T, O M, Dinter C, Lotz J, Eilers B, Wissmann C, Lott R, Meili MM, Schuetz PS, Hawa H, Sharshir M, Aburageila M, Salahuddin N, Chantziara V, Georgiou S, Tsimogianni A, Alexandropoulos P, Vassi A, Lagiou F, Valta M, Micha G, Chinou E, Michaloudis G, Kodaira A, Ikeda T, Ono S, Ueno T, Suda S, Izutani Y, Imaizumi H, De la Torre-Prados MV, Garcia-De la Torre A, Enguix-Armada A, Puerto-Morlan A, Perez-Valero V, Garcia-Alcantara A, Bolton N, Dudziak J, Bonney S, Tridente A, Nee P, Nicolaes G, Wiewel M, Schultz M, Wildhag… See abstract for full author list ➔ Bateman RM, et al. Crit Care. 2016 Apr 20;20(Suppl 2):94. doi: 10.1186/s13054-016-1208-6. Crit Care. 2016. PMID: 27885969 Free PMC article.
Evans P032 - Comparison between the new biomarker for coagulation, clot microstructure (Df) with rotational thromboelastometry (ROTEM) in patients across the sepsis spectrum S. Pillai, G. Davies, G. Mills, R. Aubrey, K. Morris, P. Williams, P. ...Shenkman P126 - Ass …
Evans P032 - Comparison between the new biomarker for coagulation, clot microstructure (Df) with rotational thromboelastometry (ROTEM) in pa …
The impact of the centrifuge characteristics and centrifugation protocols on the cells, growth factors, and fibrin architecture of a leukocyte- and platelet-rich fibrin (L-PRF) clot and membrane.
Dohan Ehrenfest DM, Pinto NR, Pereda A, Jiménez P, Corso MD, Kang BS, Nally M, Lanata N, Wang HL, Quirynen M. Dohan Ehrenfest DM, et al. Platelets. 2018 Mar;29(2):171-184. doi: 10.1080/09537104.2017.1293812. Epub 2017 Apr 24. Platelets. 2018. PMID: 28437133
Each centrifuge was opened for inspection, two accelerometers were installed (one radial, one vertical), and data were collected with a spectrum analyzer in two configurations (full-load or half load). All clots and membranes were collected into a sterile surgical b …
Each centrifuge was opened for inspection, two accelerometers were installed (one radial, one vertical), and data were collected with a s
13CH4/12CH4 sensing using Raman spectroscopy.
Petrov DV, Tanichev AS. Petrov DV, et al. Spectrochim Acta A Mol Biomol Spectrosc. 2024 Apr 4;315:124253. doi: 10.1016/j.saa.2024.124253. Online ahead of print. Spectrochim Acta A Mol Biomol Spectrosc. 2024. PMID: 38603959
In our experiments the measurement error of delta(13)C value was 10 using the 100-s exposure spectrum at a gas pressure close to 1 atm recorded on the developed Raman spectrometer. ...The data obtained make it possible to expand the capabilities of Raman gas analyzers
In our experiments the measurement error of delta(13)C value was 10 using the 100-s exposure spectrum at a gas pressure close to 1 at …
Holographic Fabry-Perot spectrometer.
Martínez-Matos O, Rodrigo JA, Vaveliuk P, Calvo ML. Martínez-Matos O, et al. Opt Lett. 2011 Feb 15;36(4):564-6. doi: 10.1364/OL.36.000564. Opt Lett. 2011. PMID: 21326457 Free article.
We propose a spectrum analyzer based on the properties of a hologram recorded with the field transmitted by a Fabry-Perot etalon. ...The proposed spectrometer could improve the operational performance of the etalon because it can exhibit high efficiency and it would …
We propose a spectrum analyzer based on the properties of a hologram recorded with the field transmitted by a Fabry-Perot etal …
Sub-Nanometer Acoustic Vibration Sensing Using a Tapered-Tip Optical Fiber Microcantilever.
Lu C, Dashtabi MM, Nikbakht H, Khoshmehr MT, Akca BI. Lu C, et al. Sensors (Basel). 2023 Jan 13;23(2):924. doi: 10.3390/s23020924. Sensors (Basel). 2023. PMID: 36679720 Free PMC article.
We demonstrate a highly sensitive acoustic vibration sensor based on a tapered-tip optical fiber acting as a microcantilever. ...Using a multimode readout fiber connected to an electric spectrum analyzer, we measured the amplitude of these power modulations o …
We demonstrate a highly sensitive acoustic vibration sensor based on a tapered-tip optical fiber acting as a microcantilever. ...Usin …
Part-Per-Billion Level Chemical Sensing with a Gold-Based SERS-Active Substrate.
Zhang T, Wu L, Pei J, Li X, Li H, Inscore F. Zhang T, et al. Sensors (Basel). 2022 Feb 24;22(5):1778. doi: 10.3390/s22051778. Sensors (Basel). 2022. PMID: 35270924 Free PMC article.
To realize such applications, we are currently developing portable and handheld trace chemical analyzers based on SERS, which are integrated with a sensor embedded with activated gold nanoparticles in a porous glass matrix. ...The results further show that the sensor is ve …
To realize such applications, we are currently developing portable and handheld trace chemical analyzers based on SERS, which are int …
Additively Manufactured Detection Module with Integrated Tuning Fork for Enhanced Photo-Acoustic Spectroscopy.
Viola R, Liberatore N, Mengali S. Viola R, et al. Sensors (Basel). 2022 Sep 22;22(19):7193. doi: 10.3390/s22197193. Sensors (Basel). 2022. PMID: 36236300 Free PMC article.
TFEPAS utilizes a non-piezoelectric metal or dielectric tuning fork to transduce the photoacoustic excitation and an optical interferometric readout to measure the amplitude of the tuning fork vibration. In particular, we have devised a solution based on Additive Manufactu …
TFEPAS utilizes a non-piezoelectric metal or dielectric tuning fork to transduce the photoacoustic excitation and an optical interferometric …
Hybrid Vibration and UV Fluorescence Technology for Rapid Imaging and Guidance for Manual Removal of Fish Bones from Fish Floss.
Wang YH, Lee KC, Wei WC, Wang CH, Liu HJ, Hou JR, Hsieh TC, Chen JK, Chen TY, Liaw SK, Lin CF, Wu CC, Chieh JJ, Chang CH. Wang YH, et al. Sensors (Basel). 2022 Nov 20;22(22):8978. doi: 10.3390/s22228978. Sensors (Basel). 2022. PMID: 36433573 Free PMC article.
The objective of the proposed human-machine cooperation (HMC) workstation is to both rapidly detect calcium-based fish bones in masses of minced fish floss and visually guide operators in approaching and removing the detected fish bones by hand based on the detection of fingernai …
The objective of the proposed human-machine cooperation (HMC) workstation is to both rapidly detect calcium-based fish bones in masses of mi …
[Spectrum peak detection algorithm based on trend accumulation without base deduction].
Jia M, Hui Z, Zhang H, Gao Y, Tong M, Ma Y. Jia M, et al. Se Pu. 2021 Jun;39(6):670-677. doi: 10.3724/SP.J.1123.2020.11009. Se Pu. 2021. PMID: 34227328 Free PMC article. Chinese.
The algorithm omits the base subtraction and spectral peak classification steps and instead detects spectral peaks directly based on the source data curve. In a traditional spectrum peak detection algorithm, the spectrum peak classification depends on determining a …
The algorithm omits the base subtraction and spectral peak classification steps and instead detects spectral peaks directly based on the sou …
Intraoperative detection of human meningioma using a handheld visible resonance Raman analyzer.
Zhang L, Zhou Y, Wu B, Zhang S, Zhu K, Liu CH, Yu X, Alfano RR. Zhang L, et al. Lasers Med Sci. 2022 Mar;37(2):1311-1319. doi: 10.1007/s10103-021-03390-2. Epub 2021 Aug 8. Lasers Med Sci. 2022. PMID: 34365551
To report for the first time the preliminary results for the evaluation of a VRR-LRR analyzer based on visible resonance Raman technique to identify human meningioma grades and margins intraoperatively. ...The VRR-LRR analyzer demonstrates a new approach for label-f …
To report for the first time the preliminary results for the evaluation of a VRR-LRR analyzer based on visible resonance Raman techni …
51 results